UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
Heat Majic™
Models FVF18PW,
FVF24PW, and
FVF30PW (Millivolt)
Remote Ready
ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
P
I
L
O
T
O
F
F
O
N
LO
O
F
F
O
N
A
U
T
O
HI
Save this manual for future reference.
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For as-
sistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design
certified for these installations in accor-
dance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should
not be used with unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation
section on page 4 of this manual.
Patent Pending
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - PROPANE/LP GAS LOG HEATER

UNVENTED (VENT-FREE)PROPANE/LP GAS LOG HEATERHeat Majic™Models FVF18PW,FVF24PW, andFVF30PW (Millivolt)Remote ReadyALSO DESIGN-CERTIFIED AS A VENTED DE

Strona 2 - INFORMATION

10105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDINSTALLATIONContinuedINSTALLING HEATER BASEASSEMBLY WARNING: If installi

Strona 3

11105194OWNER’S MANUALCONNECTING TO GASSUPPLY WARNING: A qualified serviceperson must connect heater togas supply. Follow all local codes. CAUTION: Ne

Strona 4 - VENTILATION

12105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDONPOSITIONOFFPOSITIONFigure 15 - Equipment Shutoff ValveOpenClosedEquipm

Strona 5

13105194OWNER’S MANUALAUTOOFFONAUTOOFFONOFFPILOTONHILOHILOINSTALLATIONContinuedFigure 16 - Checking Gas Joints WARNING: Failure to posi-tion the parts

Strona 6

14105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDOFFPILOTONLOIHAUTOOFFON1. STOP! Read the safety informationin column 1.2

Strona 7

15105194OWNER’S MANUALFigure 21- PilotIgnitorElectrodePilot Burner9. Slightly push in and turn controlknob counterclockwise to theON position.10. Wa

Strona 8

16105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDOPERATINGHEATERContinuedFigure 22 - Setting the Selector Switch, Control

Strona 9

17105194OWNER’S MANUALTROUBLESHOOTING WARNING: Turn off heaterand let cool before servicing.Only a qualified service personshould service and repairh

Strona 10 - INSTALLATION

18105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDOBSERVED PROBLEMBurner does not light after ODS/pilot is litDelayed igni

Strona 11 - OWNER’S MANUAL

19105194OWNER’S MANUALTROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any

Strona 12

2105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDSAFETYINFORMATION DANGER: Carbon monoxidepoisoning may lead to death!Carb

Strona 13

20105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDREPLACEMENTPARTSNote: Use only original replacement parts.This will prot

Strona 14 - OPERATING

21105194OWNER’S MANUALSPECIFICATIONSHeat Majic™ 18" Heat Majic™ 24" and 30"Remote Ready Remote ReadyBtu 17,500/27,000 19,000/31,500Type

Strona 15

22105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDILLUSTRATEDPARTSBREAKDOWNHEAT MAJIC™ LOG MODELSFVF18PW, FVF24PW, ANDFVF3

Strona 16 - INSPECTING

23105194OWNER’S MANUALPARTS LISTThis list contains replaceable parts used in your heater. When ordering parts, follow theinstructions listed under Rep

Strona 17

105194-01Rev. D03/02NOT A UPCKEEP THIS WARRANTYWARRANTY INFORMATIONAlways specify model and serial numbers when communicating with the factory.We rese

Strona 18 - TROUBLESHOOTING

3105194OWNER’S MANUALAUTOOFFONOFFPILOTONHILOHILOPRODUCTIDENTIFICATIONLOCAL CODESInstall and use heater with care. Follow alllocal codes. In the absenc

Strona 19

4105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDPROVIDING ADEQUATEVENTILATIONThe following are excerpts from NationalFuel

Strona 20 - REPLACEMENT

5105194OWNER’S MANUALDETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined SpaceUse this work sheet to determ

Strona 21

6105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDAIR FORCOMBUSTION ANDVENTILATIONContinuedVENTILATION AIRVentilation Air F

Strona 22 - BREAKDOWN

7105194OWNER’S MANUALLOG SIZING REQUIREMENTSLog Minimum FireboxSize Height Depth Front Rear *Width Width18" 17" 14" 24" 20"24

Strona 23

8105194UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INCORPORATEDINSTALLATIONContinuedMinimum NoncombustibleMaterial ClearancesIf Not Usin

Strona 24 - WARRANTY INFORMATION

9105194OWNER’S MANUALFigure 7 - Minimum Mantel Clearances When Using HoodINSTALLATIONContinuedFigure 6 - Minimum Mantel Clearances Without Using HoodM